12 - 272
12.7 Special Relay List
12
TROUBLESHOOTING
*6: The Q03UDCPU, Q04UDHCPU, Q06UDHCPU, Q13UDHCPU, and Q26UDHCPU whose first 5 digits of serial number is "10012" or later.
Table12.28 Special relay
Number Name Meaning Explanation
Set by
(When Set)
Corres-
ponding
ACPU
M9
Corresponding
CPU
SM56 Operation error
OFF : Normal
ON : Operation error
ON when operation error is generated
Remains ON if the condition is restored to normal
thereafter.
S (Error) M9011
SM60 Blown fuse detection
OFF : Normal
ON : Module with blown
fuse
Turns ON if there is at least one output module
whose fuse has blown.
Remains ON if the condition is restored to normal
thereafter.
Blown fuse status is checked even for remote I/O
station output modules.
S (Error) M9000
Rem
SM61 I/O module verify error
OFF : Normal
ON : Error
Turns ON if the I/O module differs from the status
registered at power on.
Remains ON if the condition is restored to normal
thereafter.
I/O module verification is also conducted for remote
I/O station modules.
S (Error) M9002
SM62 Annunciator detection
OFF : Not detected
ON : Detected
Goes ON if even one annunciator F goes ON.
S (Instruction
execution)
M9009
SM80 CHK detection
OFF : Not detected
ON : Detected
Goes ON if error is detected by CHK instruction.
Remains ON if the condition is restored to normal
thereafter.
S (Instruction
execution)
New
QnA
Qn(H)
QnPH
QnPRH
SM90
Startup of monitoring
timer for step transition
(Enabled only when
SFC program exists)
OFF : Not started(monitoring
timer reset)
ON : Started(monitoring
timer started)
Corresponds to SD90
Goes ON when
measurement of step
transition monitoring timer
is commenced.
Resets step transition
monitoring timer when it
goes OFF.
U
M9108
QnA
Qn(H)
QnPH
QnPRH
SM91 Corresponds to SD91 M9109
SM92 Corresponds to SD92 M9110
SM93 Corresponds to SD93 M9111
SM94 Corresponds to SD94 M9112
SM95 Corresponds to SD95 M9113
SM96 Corresponds to SD96 M9114
SM97 Corresponds to SD97 New
SM98 Corresponds to SD98 New
SM99 Corresponds to SD99 New
SM100
Serial communication
function using flag
OFF : Serial communication
function is not used.
ON : Serial communication
function is used.
Stores the setting of whether the serial
communication function is used or not in the serial
communication setting parameter
S (Power-ON or
reset)
New Q00J/Q00/Q01
SM101
Communication
protocol status flag
OFF : GX Developer
ON : MC protocol
communication device
Stores whether the device that is communicating via
the RS-232 interface is GX Developer or MC protocol
communication device
S (RS232
communication)
SM110 Protocol error
OFF : Normal
ON : Abnormal
Turns ON when an abnormal protocol was used to
make communication in the serial communication
function.
Remains ON if the condition is restored to normal
thereafter
S (Error)
SM111 Communication status
OFF : Normal
ON : Abnormal
Turns ON when the mode used to make
communication was different from the setting in the
serial communication function.
Remains ON if the condition is restored to normal
thereafter.
S (Error)
SM112 Error information clear ON : Cleared
Turns ON when the error codes stored in SM110,
SM111, SD110 and SD111 are cleared. (Activated
when turned from OFF to ON)
U
SM113 Overrun error
OFF : Normal
ON : Abnormal
Turns ON when an overrun error occurred in the
serial communication error.
S (Error)
SM114 Parity error
OFF : Normal
ON : Abnormal
Turns ON when a parity error occurred in the serial
communication error.
S (Error)
SM115 Framing error
OFF : Normal
ON : Abnormal
Turns ON when a framing error occurred in the serial
communication error.
S (Error)
SM165
Program memory
batch transfer
execution status
OFF : Completed
ON : Notexecuted or
execution under way
Turns ON when data are written to the program cash
memory.
Turns OFF when the program batch transfer has
been completed.
ON status is held when the program batch transfer is
not performed after data are written to the program
memory.
S (Status change) New
QnU
*6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Q01CPU and is the answer not in the manual?

Mitsubishi Q01CPU Specifications

General IconGeneral
BrandMitsubishi
ModelQ01CPU
CategoryController
LanguageEnglish

Related product manuals