Engineering
26
12/03 AWB-C27-1293GB
Connect MI4
(hand-held) to PLC
Sucom A (through CN3)
PLC connection through Sucom A is preset (see
Section “Delivery state” above). The terminal
assignment on the PLC side is identical to that of the
PLC PORT; see page 13.
Suconet K (through CN1)
PLC connection through Suconet K is preset (see
Section “Delivery state” above). The terminal
assignment on the PLC side is identical to that of the
AUX PORT; see page 14.
CN 1.1 ------- (brown-pink) ---------
CN 1.2 ------- (orange-pink) --------
CN 1.5 ------- (yellow-pink) ----------- Suconet K.3
CN 1.6 -------- (green-pink) ------------ Suconet K.7
Siemens MPI (through CN1)
If the ZB4-505-IF1 MPI communication cable is
connected, the CN1 AUX PORT must be rewired as
follows:
Plug No. 6 (green/pink) to plug No. 4 (see Section
“Delivery state” above)
The terminal assignment on the PLC side is identical
to that of the AUX PORT; see page 17.
CN 1.1 ------- (brown-pink) --------- MPI.5
CN 1.2 ------- (orange-pink) --------
CN 1.4 ------- (yellow-pink) ----------MPI.8
CN 1.5 -------- (green-pink) -----------MPI.3
Connecting the MI4
(hand-held) to PC or
printer (through CN2)
The PC connection is preset (see Section “Delivery
state” above).
The terminal assignment on the PC side is identical
to that of the PC/PRINTER PORT or the PLC-PORT;
see page 21.