Trouble-shooting
Revision 3
© Moffat Ltd, September 2009
E32SUBC OVEN and PROOFER
ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY
QUALIFIED PERSONS ONLY.
WARNING:
5.1 Error Messages
Oven
Door open Door open, Microswitch faulty
Probe open error Oven temperature probe open circuit
Probe short error Oven temperature probe short circuit
Hi temp error Oven temperature + 25
o
C
Proofer
Air probe open error Proofer air temperature open circuit
Air probe short error Proofer air temperatures short circuit
Air Hi Temp error Proofer temperature + 25
o
C
Water probe open error Proofer water temperature probe open circuit
Water probe short error Proofer water temperature probe short circuit
Water Hi Temp error Water tank over temperature + 25
o
C
Water low error Proofer water level low for more than 30 secs
Humidity short error Short in probe or between blue/yellow wires
Humidity open error Open circuit in humidity probe or
Short between white/yellow wires
Blue or Yellow wires disconnected
97% Actual humidity reading White wire disconnected.
Unit shuts down will not start Short circuit between Blue/ White wire to humidity probe
Blown controller fuse.