EasyManua.ls Logo

Moffat turbofan E32SUBC - Fault Codes

Moffat turbofan E32SUBC
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
References
63
Revision 3
© Moffat Ltd, September 2009
E32SUBC OVEN and PROOFER
Fault codes
Message Beep Fault Soft off
Oven
Door open Yes Door open, Microswitch faulty Yes
Probe open error Yes Oven temperature probe open circuit Yes
Probe short error Yes Oven temperature probe short circuit Yes
Hi temp error Yes Oven temperature + 25
o
C Yes
Proofer
Air probe open error Yes Proofer air temperature open circuit Yes
Air probe short error Yes Proofer air temperatures short circuit Yes
Air Hi Temp error Yes Proofer temperature + 25
o
C Yes
Water probe open error Yes Proofer water temperature probe open circuit Yes
Water probe short error Yes Proofer water temperature probe short circuit Yes
Water Hi Temp error Yes Water tank over temperature + 25
o
C Yes
Water low error Yes Proofer water level low for more than 30 secs Yes
Humidity short error Yes Short in probe or between blue/yellow wires Yes
Humidity open error Yes Open circuit in humidity probe or Yes
Short between white/yellow wires
Blue or Yellow wires disconnected
97% Actual humidity reading Yes White wire disconnected. Yes
Unit shuts down will not start Short circuit between Blue/ White wire to humidity probe
Blown controller fuse.