C-75 Installation Guide
25
set communication
key
Sets the AP-server shared secret. You must enter a hexadecimal value, of length 32,
as the shared secret. It can be used instead of the set communication passphrase
command. Use this command if you are comfortable working with hexadecimals.
set communication
key default
Sets the communication key to its default value.
set communication
passphrase
Sets the AP-server shared secret. You must enter a character string, of length
between 10 and 127, as the shared secret. The string is internally converted to
hexadecimal format. It can be used instead of the set communication key command.
set presence
notification
parameters
Sets the presence notification parameters. The parameters for presence notification
are the RSSI value in dbm, IP address/hostname of the presence notification server
and time interval in seconds. The RSSI value can range between -127 and 0 dbm. The
time interval can range between 0 and 14400 seconds.