EasyManua.ls Logo

Mostek z80 - %-Test Memory Command; Description of % Command

Default Icon
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-50
3.73
%-TEST
MEMORY
CCMVlAND
FORMAT:
'.!
s,f
(CR)
, .!
s,
f , 0 (
CR)
3.74
DESCRIPTION,
%
COMMAND
<
Test
Target
memory
<
Test
with
options.
The
%
command
is
used
to
test
Target
RAM.
(1)
(2)
Fonnat
(1)
will
run a sequence
of
tests
of
Target
RAM
starting
at
address
s
through
f.
If
a
failure
occurs,
the
hexadecimal
address,
data
and expected
data
will
be
printed.
The
following
tests
are
perfonned.
TEST
1 Write 0
to
each
location
and
check.
TEST
2 Write
0FE~
to
each
location
and check.
TEST
3 Write
055H
and
0AAH
to
each
location
and check.
Fonnat (2) allows
testing
to
be
perfonned on system,
target,
or
interface
memory,
if
S,
T,
or
I,
respectively,
is
entered
as
the
option.
Attempting
to
test
system
memory
from 0
to
4000H
will
overwrite
the
AIMZ80A
program
itself,
and,
of
course,
won't
work.
3.75
EXAMPLES,
%
COMMAND
TEST
01
PASSED
TEST
02
PASSED
TEST
03
PASSED
,