TEST SETUP & TESTING for 380–430 MHz and 410–470 MHz 5.1 - 1
CHAPTER 5.1
TEST SETUP & TESTING
for 380–430 MHz and 410–470 MHz
Typical Test Setup
Before Testing
Carry out the following instructions before testing:
• Connect the DC cable to the DC connector on the terminal.
• Connect the other side of the DC cable to the DC output connector on the power supply
• Connect an RF cable to the N-type RF Connector of the IFR.
• Connect the other side of the RF cable to the antenna connector on the terminal.
• Set the DC voltage on the power supply to 13.2 Volts.
• Switch on the terminal.
Figure 5.1-1 Typical Test Setup
Any level 3 repairs can deeply affect the performance of the MTM800 with
Enhanced Control Head terminal and may cause a new tuning procedure.
This tuning procedure can only be applied by certain authorized Motorola
depots where the appropriate TEST&TUNE EQUIPMENT is available.
The appropriate TEST&TUNE EQUIPMENT is a special automated test
equipment which is only available at some Motorola factories and Motorola
repair centers.
!
W A R N I N G
!