EasyManua.ls Logo

Moxa Technologies AirWorks AWK-1131A - Page 16

Moxa Technologies AirWorks AWK-1131A
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AirWorks AWK-1131A Getting Started
2-4
How to Test Two or More AWK-1131A Units
If you have two or more AWK-1131A units, you will need a second notebook computer (Notebook B) equipped
with an Ethernet port. Use the default settings for the first AWK-1131A connected to notebook A and change
the second or third AWK-1131A connected to notebook B to Client mode, and then configure the notebooks and
AWK-1131A units properly.
After setting up the testing environment, open a DOS window on notebook B. At the prompt, type:
ping <IP address of notebook A>
and then press Enter. A Reply from IP address …response means the communication was successful. A
Request timed outresponse means the communication failed. In this case, recheck the configuration to make
sure the connections are correct.