AirWorks AWK-1131A Web Console Configuration
3-27
Write community (for V1, V2c)
Setting Description Factory Default
V1, V2c Read /Write
Community
Use a community string match with a maximum of 31
characters for authentication. This means that the SNMP
agent
can accesses all objects with read/write permissions using this
community string.
private
SNMP agent version
Setting Description Factory Default
V1, V2c, V3, or
V1, V2c, or
V3 only
Select the SNMP protocol version used to manage the switch. V1, V2c
Admin auth type (for V1, V2c, V3, and V3 only)
Setting Description Factory Default
No Auth Use admin account to access objects. No authentication No Auth
MD5 Provide authentication based on the HMAC-MD5 algorithms.
8-character passwords are the minimum requirement for
authentication.
SHA Provides authentication based on
HMAC-SHA algorithms. 8-character passwords are the
minimum requirement for authentication.
Admin private key (for V1, V2c, V3, and V3 only)
Setting Description Factory Default
Disable No data encryption Disable
DES DES-based data encryption
AES AES-based data encryption
Private Key
A data encryption key is the minimum requirement for data encryption (maximum of 63 characters)
Private MIB Information Device Object ID
Also known as OID, this is AWK-1131As enterprise value, which is a fixed value.
Link Fault Pass-Through (for Client mode only)
This function means if Ethernet port is link down, wireless connection will be forced to disconnect. Once
Ethernet link is recovered, AWK will try to connect to AP.
If wireless is disconnected, AWK restarts auto-negotiation on Ethernet port but always stays in the link failure
state. Once the wireless connection is recovered, AWK will try to recover the Ethernet link.
System log will indicate the link fault pass through events in addition to the original link up/down events.
Link Fault Pass-Through
Setting Description Factory Default
Enable Enables Link Fault Pass-Through Disable
Disable Disables Link Fault Pass-Through

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies AirWorks AWK-1131A and is the answer not in the manual?

Moxa Technologies AirWorks AWK-1131A Specifications

General IconGeneral
BrandMoxa Technologies
ModelAirWorks AWK-1131A
CategoryWireless Access Point
LanguageEnglish

Related product manuals