6 Installation and commissioning
72 5831400/02 EN
3. Connect the wires at the free end of the connection cable in the control
cabinet in accordance with the supplied connection diagram.
Figure54: Connection assignment, view of installed M plug
1 Coding contour
A Black B Red
C Blue D Orange
E Yellow F Brown
G Red/black H Blue/black
I Orange/black J Yellow/black
K Brown/black L Black/red
M - N -
6.4.7.4 Connection for micro-switches via ANSI plug (Compact RM)
Devices with a plug connection may be set up with either only
extra-low-voltage circuits or only low-voltage circuits using the
device plug.