EasyManua.ls Logo

MSA LUNAR - After each Use

MSA LUNAR
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ensure LUNAR battery is charged.
Ensure LUNAR powers on.
Ensure Motion Alarm activates when LUNARdoes not move for an extended period.
Ensure a Manual Alarm can be activated.
Ensure a search can be started.
Ensure the Thermal Image is clear and responsive.
The LED blinks green slowly to indicate normal operation. If any of these criteria above are not met and the LED is not blinking
green, remove the device from service until the condition is addressed.
In addition to the LUNAR inspection, ensure the LUNAR device is properly connected to the desired SCBA or external device:
(1) Activate an alarm on the connected SCBA or external device.
(2) Ensure the alarm appears on the LUNAR device.
(3) Cancel the alarm on the connected SCBA or external device.
For more information on activating and canceling an alarm on an SCBA or external device, see the device's user instruction
manual.
WARNING!
When pairing LUNAR with an external device, LUNAR must only be paired to the external device being worn by the User of
the LUNAR. Failure to pair the two devices or pairing the LUNAR with an external device being worn by another User can
result in unintended alarm communications including, but not limited to:
Unintended deactivation of the motion sensing alarm on LUNAR
Command center alarms not being received or being received by an unintended User
External device or LUNAR alarms not being received by the command center or appearing to come from a different User
than the one experiencing the alarm
Incorrect alarm information being sent to searchers resulting in the searchers targeting the wrong LUNAR device to locate a
User in distress
Failure to follow these warnings can result in serious personal injury or death.
4.8.9 After Each Use
Keep the battery installed for cleaning and disinfection to ensure the connector port remains clean and dry.
Depending on the cleaning policy adopted, either a designated person or the User should clean the LUNAR after each use to
limit exposure to possible contamination that may be present on the unit after firefighting activities. ANSI standards suggest
that Users should be trained in the cleaning procedure.
Confidence Plus® Cleaning Solution ( 10009971) from MSA is recommended. It cleans and disinfects in one operation. It
retains its germicidal efficiency in hard water to inhibit the growth of bacteria. It will not deteriorate rubber, plastic, glass, or
metal parts. Refer to the label to prepare the Confidence Plus Cleaning Solution.
If the Confidence Plus Cleaning Solution is not used, wash in a mild cleaning solution, rinse thoroughly.
After cleaning and disinfection:
Carefully clean the Display and TIC lens with a lint-free, isopropyl alcohol wipe.
Carefully dry using a soft, lint-free cloth. Avoid scratching the Display and TIC lens.
Ensure the germanium window Display and TIC lens do not have debris, cracks or other visible damage.
MSA LUNAR 31