EasyManua.ls Logo

MSA PrimaX P - IECEx Marking and Certificates

MSA PrimaX P
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MSA
Approvals
PrimaX
52
GB
7.2 Marking and Certificates according to IECEx
PrimaX P
Manufacturer: MSA AUER GmbH
Thiemannstraße 1
D-12059 Berlin
Product: PrimaX P
Type of protection: IEC 60079-0:2007, IEC 60079-1:2007,
IEC 60079-11:2006, IEC 60079-31:2009
Measuring function for explosion protection: no
Gas: see manual
Marking: Prima X P
Ex d [ia] IIC T4 Gb
Ex t [ia] IIIC T130°C Db
-40°C Ta +70°C
P
i
770 mW, U
i
28 V, I
i
110 mA, L
i
= 0, C
i
= 0
Option: HART Module Connector, only for temporary connection of
an intrinsic safe HART Field Communicator
P
o
200 mW, U
o
2,7 V, I
0
140 mA, L
o
10 µH, C
o
1nF
P
i
5mW, U
i
5 V, I
i
1 mA, L
i
= 0, C
i
= 0
IEC-Type Examination Certificate:IECEx BVS 10.0043 X
Quality Assurance Notification: 0158
Year of Manufacture: see Label
Serial Nr.: see Label