Installation and User Guide
PE653RC
Pool/Spa Control System

Table of Contents

Questions and Answers

  • D
    Daniel YoungAug 13, 2025
    What to do if the PE653 Device appears to be ‘LOCKED UP’ in Multi Wave Control Systems?
    • K
      Kevin MartinezAug 13, 2025
      If the PE653 device appears to be locked up, power down the PE653 device to reset it.
  • A
    Anne RileyAug 16, 2025
    What to do if the Hand-Held Controller appears to be “LOCKED UP” in Multi Wave PE653RC Control Systems?
    • A
      angel67Aug 16, 2025
      If the Hand-Held Controller appears to be locked up, power down the Controller to reset it.
  • C
    Catherine RamirezAug 20, 2025
    What to do if the circuit breaker for the pump trips every time that the Pump turns ON in Multi Wave PE653RC?
    • J
      Jeffrey StevensAug 20, 2025
      If the circuit breaker for the pump trips each time the pump turns on, confirm that the system is programmed for a 2-speed pump, check the wiring for a 2-speed pump, and confirm that the controls in the heater are turned ON.
  • J
    Jordan LewisAug 25, 2025
    Why high speed and low speed circuits turn ON together when the pump is turned ON in Multi Wave PE653RC?
    • J
      John MaldonadoAug 25, 2025
      If both high and low speed circuits activate simultaneously when the pump is turned on, confirm that the system is programmed for a 2-speed pump. If needed, reprogram the system for 2-speed pump operation.
  • R
    Rebecca CunninghamAug 27, 2025
    What to do if water or moisture is visible inside the screen of the Hand-Held Controller in Multi Wave PE653RC Control Systems?
    • V
      vthompsonAug 28, 2025
      If water or moisture is visible inside the screen of the Hand-Held Controller, dry out the Hand-Held Controller.
  • E
    Erin JimenezSep 1, 2025
    What to do if the 2-speed pump will not operate in 2-Speed mode in Multi Wave Control Systems?
    • C
      Charles ThomasSep 1, 2025
      If the 2-speed pump will not operate in 2-Speed mode, verify that all wiring connections are correct and secure, that the correct voltage is present at terminals 1 and 2 and that your system is configured for a 2-speed pump. For pump assistance, contact your pump service company.
  • A
    Alexis BishopSep 4, 2025
    Why the heater turns OFF but gets very hot after the pump turns OFF in Multi Wave PE653RC?
    • M
      Mrs. Susan JonesSep 5, 2025
      If the heater turns off but gets very hot after the pump turns off, verify that the heater has a proper “Time Interval” programmed for cool down.
  • E
    Erin MejiaSep 8, 2025
    What to do if the system appears to work, the LEDs turn ON and OFF but the power circuits and attached equipment will not turn ON in Multi Wave Control Systems?
    • D
      douglas35Sep 8, 2025
      If the system appears to work, the LEDs turn ON and OFF but the power circuits and attached equipment will not turn ON, verify that the voltage is correct at the PE653 power terminals.

Summary

Important Safety Instructions

General Safety Precautions

Covers risks of injury, hyperthermia, and health considerations.

Electrical Safety and Grounding

Addresses risks of electric shock and installation requirements.

Section 3: Installing and Wiring the PE653 Receiving Device

Wiring Instructions

Explains power connections and terminal assignments for the PE653.

Installation Instructions

Step-by-step guide for physically installing the PE653 enclosure.

Low-Voltage Wiring

Motorized Valve Actuator Connection and Synchronizing

Section 4: Programming the PE953 Hand-Held Controller

Creating Network Connection

Steps to establish communication between the controller and receiver.

Deleting Existing Programming

Procedure to clear previous settings before setup.

Resetting the PE953 Hand-Held Controller

Resetting the PE653 Receiving Device

Linking Hand-Held to PE653 Receiver

Configuring 1-Speed or 2-Speed Pump

Configuring Booster (Cleaner) Pump

Configuring Fireman Switch Time Interval

Setting Up Schedules

Configuring Variable Speed Pump (Optional)

Section 6: Advanced Features

Configuring Multiple Hand-Held Controllers

Setting up multiple controllers for the system.

Changing Secondary to Primary Control

Section 7: Programming for Z-Wave Devices

Deleting Existing Z-Wave Programming

Clearing existing Z-Wave device programming before inclusion.

Including Z-Wave Devices into Network

Adding Z-Wave Devices to Scenes

Setting Up Z-Wave Associations

Section 8: Using PE953 with PE650 Device

Linking PE953 Controller with PE650 Receiver

Connecting the PE953 to control a PE650 network.

Section 10: Troubleshooting

System Indicators On, Equipment Off

Diagnosing issues where indicators work but equipment does not.

2-Speed Pump Not Operating Correctly

Simultaneous High;Low Pump Speed Activation

Pump Breaker Trips on Startup

Heater Not Turning ON

Heater Overheating After Pump Shutdown

System Not Responding to Hand-Held Commands

Moisture in Hand-Held Controller Screen

Hand-Held Controller Locked Up

PE653 Device Locked Up

Section 12: Warranty

One Year Limited Warranty

Details of the product's one-year limited warranty.

Multi Wave PE653RC Specifications

General IconGeneral
BrandMulti Wave
ModelPE653RC
CategoryControl Systems
LanguageEnglish