10 Part Number: WBL-95-156 REV002
General Information Section 1
DRAIN CONNECTIONS
Models FB081TF
Drain OUT
(1½ NPS Male)
Drain lines must have a 1.5 inch drop per 5 feet of run
(2.5 cm per meter), and must not create traps.
The floor drain must be large enough to accommodate
drainage from all drains.
An air gap is required for back flow prevention. Plumb
to local code.
Water Requirements
n
Warning
Connect to a potable filtered water supply only.
SUPPLY CONNECTIONS
Plain
Water
IN Quick
Connect
Rear of the Unit
Use a male quick connect (supplied PN: WBL-96-087) and
6’ (1.8 m) of beverage tubing to connect labeled coupling
body fitting(s) on back of unit for the supply connection.
Do not connect water to a hot water supply. Be sure all
hot water restrictors installed for other equipment are
working. (Check valves on sink faucets, dishwashers, etc.)
Install a water shut-off valve in the water line at the rear
of the machine.
Insulate water inlet lines if condensation is an issue.
Equipment to be installed with adequate back flow
protection that meets all applicable national, state, and
local codes.
HARD WATER
All source water must be filtered. In areas where the water is
highly concentrated with minerals the water should be tested
by a water treatment specialist, and the recommendations of
the specialist regarding filtration and/or treatment should be
followed.