EasyManuals Logo
Home>Multiplex>Dispenser>FreshBlender

Multiplex FreshBlender User Manual

Multiplex FreshBlender
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8 Part Number: WBL-95-156 REV002
General Information Section 1
PRODUCT DELIVERY LOCATION
The location selected for the FreshBlender Beverage System
must meet the following criteria.
The air temperature must be at least 40°F (4°C), but
must not exceed 90°F (32°C), climate class 4.
The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
Plain Inlet Water Temperature:
min/max = 40°F / 90°F (4°C / 32°C).
Always use the water supply line supplied when
installing this appliance. Never reuse an old supply line.
Verify floor of install location is level front to back, side
to side.
Keep equipment area clear of combustible material.
n
Warning
Carbon Dioxide (CO
2
) displaces oxygen. Exposure to a
high concentration of CO
2
gas causes tremors, which
are followed rapidly by loss of consciousness and
suffocation. If a CO
2
gas leak is suspected, particularly
in a small area, immediately ventilate the area before
repairing the leak. CO
2
lines and pumps must not be
installed in an enclosed space. An enclosed space can
be a cooler or small room or closet. This may include
convenience stores with glass door self serve coolers. If
you suspect CO
2
may build up in an area, venting of the
B-I-B pumps and / or CO
2
monitors must be utilized.
Clearances
Top 18" (46 cm)
Sides 0" (0 cm)
Back 6" (15 cm)
Front 24" (61 cm)
n
Warning
Do not obstruct machine vents or openings.
Heat of Rejection
Model System BTU
FB081TF 2300 BTU/hr (average)
REFRIGERANT CHARGE
Important
Due to continuous improvements, this information is
for reference only. Please refer to the serial number tag
to verify electrical data. Serial tag information overrides
information listed on this page.
Model System R404A
FB081TF
1
(Lower Cabinet)
8 oz
(226.8 g)
2
(Ice Maker)
ICE MAKER PRODUCTION
Acceptable incoming water temperature range is 40°F (4°C)
to 90°F (32°C). Optimum Range is 45°F (7°C) to 50°F (10°C)
(Target 50°F [10°C], results based on ARI capacity testing @
70°F [21°C] air temperature).
R-404a Ice Production
Air Temperature/
Water Temperature
24 Hour Ice
Production
kWh/100 lbs (45 kg)
@ 90°/70°F (32°/21°C)
70°/50°F
(21°/10°C)
261 lbs
(118 kg)
8.69
90°/70°F
(32°/21°C)
185 lbs
(84 kg)
Water usage/100 lbs./45.4 kgs of Ice
Potable Water: 12 gallons, 45.4 liters

Table of Contents

Other manuals for Multiplex FreshBlender

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Multiplex FreshBlender and is the answer not in the manual?

Multiplex FreshBlender Specifications

General IconGeneral
BrandMultiplex
ModelFreshBlender
CategoryDispenser
LanguageEnglish

Related product manuals