68 Part Number: WBL-95-156 REV002
Maintenance Section 4
Annual Planned Maintenance
The following parts are recommended for annual planned
maintenance replacement to ensure optimum unit
performance and minimize downtime:
• Refrigerator door gasket (cleaning may be sufficient)
• Two (2) #6 O-rings for the water and CIP hose quick
connect lines
• Dispense Head Assembly including LMS valves
• Blender Shaft Assembly
• Shuttle Components
• Sanitation Fittings
The evaporator for the on board ice maker should be
inspected at least once a year. The evaporator service life
also depends on the water quality and environment. More
frequent inspection and maintenance are recommended to
keep performance of this ice maker optimized.
NOTE: All planned maintenance must be done by an
approved, certified Manitowoc Field Service Technician.