Technical specifications
32 13.05.2014
Inert gas (option)
Max. input pressure 2.5 bar
Min. input pressure 0.7 bar
Inner diameter of supply line 8 mm
Vacuum pump
Nominal suction capacity
• 10 m
3
/h
• 12 m
3
/h
Achievable final pressure approx. 2 mbar
Noise exposure at the workplace
Based on Machinery Directive
(2006/42/EC)
Measuring instrument Sound level meter, IEC 61672- 1,
class 1, error limit +/-1.1 dB
Condition of the machine New condition with optimum set-
tings at the time of delivery.
A-weighted emission sound-
pressure level at the workplace
L
pA
(DIN ISO 11204, accuracy
class 3)
<70 dB
0,5 m
1,55 m
0,7 m
A
A
Fig. 19: Noise exposure measuring point