+44 (0)23 8052 2345
31
MV Heating UK Ltd
Step 4: Next step is adjusting the heating time. You can adjust
this in the same way using the arrow keys. The hour first followed by the
minutes, pressing the ‘heating icon’ again to confirm and the ‘P’ key for the
final time to complete the task.
Note: The ‘confirmation dot’ in the upper right hand corner of the screen
must be present each time a step is adjusted to confirm it.
Checking Temperature
Pressing the ‘P’ and ‘up’ arrow button simultaneously whilst in the heating
mode will display the air inlet temperature, or the remote temperature
sensor probe’s temperature if one is fitted.
Note:
• The display will show 0°C if the temperature is lower than 0°C
• The display will automatically revert to the heating mode if left idle
for more than 5 seconds
Converting to Thermostatic Mode
Press both arrow keys to manually change from the heating mode to the
thermostatic mode.
Fault Information
The fault display can be accessed by pressing the ‘P’ button during the
heating mode.
Six fault codes can be checked by pressing the arrow keys.
To return to the heating mode, press the heating button.
To eliminate the fault information; press the ‘P’ and heating buttons
simultaneously.