EasyManua.ls Logo

MV Heating MV Airo 2 - Fault Codes; Rheostat Control Faults

MV Heating MV Airo 2
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
+44 (0)23 8052 2345
44
MV Heating UK Ltd
Fault Codes
Rheostat Control
When the ECU had discovered a fault, the rheostat control will flash a fault
code. The control should therefore be ideally placed where it can be clearly
seen and accessed.
The faults will be displayed as short flashes followed by long flashes. To
determine the code, you must count the number of long flashes.
Number of
Long Flashes
Cause of Problem
1
Failure of second start
2
Termination of the third time of combustion
3
Voltage power out of specified range
4
Glow plug temperature increases slowly
5
Air heaters will not flash 5 times
6
Temperature sensor: Broken circuit or short-circuit
7
Fuel pump: Broken circuit or short-circuit
8
Fan motor: Broken circuit, short-circuit or clogged
9
Glow pin: Broken circuit or short-circuit
10
Overheated
11
Overheat sensor: Broken circuit or short-circuit
12
Control switch: Broken circuit or short-circuit

Other manuals for MV Heating MV Airo 2