12
MV Heating UK Ltd
Installation of the Main Heater Body
For the ease of servicing, fault finding and air flow it’s recommended that the
main body is placed in an area with easy access. Figure VI shows the
minimum distances required.
Figure VI
A. Air heating inlet B. Air heating outlet
C. Combustion air inlet D. Fuel inlet
E. Exhaust outlet F. Non-interference area
G. Information label H. Installation surface
I. Gasket
Choose a flat installation surface, any undulations could cause the case to
twist and will not ensure an even mount. Make sure there are no foreign
bodies between the bottom of the heater and the installation surface itself.
This will ensure a good seal between the two. File down any drill holes to
again ensure an even mounting surface. Tighten the M6 bolts provided to a
torque setting of 6Nm+1Nm.
Figure VII shows the position of the installation holes. If the installation area
is less than 1.5mm thick a mounting plate will be required (Figure VIII).