33 Accelaterm
®
Installation and Service Manual
SPECIFICATIONS
Environmental and Regulatory Quantity Comments
Temperature Range Operating
Temperature Range Storage
32 - 120°F (0 - 49°C)
32 - 149°F (0 - 65°C)
Relative Humidity 0% to 85% non-condensing
Compliance
UL294 Access Control (USA) 115VAC 60Hz only
CE Mark (EU)
Configurable from Host Quantity Comments
Time Schedules 128 Standard
Access Groups 1000 Standard, configurable and expandable from Host
Link Programs 64 Standard
Facility Codes 10 Standard
Transaction Buffer 1000 Standard, configurable and expandable
Cables AWG Type Maximum Length
Alarm Inputs 22 Stranded, shielded, w/drain 2-conductor
500 ft
(153m)
Readers:
Magnetic Stripe & Wiegand/Proximity
22
Stranded, shielded, w/drain 5-conductor
(DO NOT use twisted-pair cables)
500 ft
(153m)
Polling Line
EIA/TIA-485 (Network)
22
Stranded, shielded, w/drain
2-twisted pair
500 ft
(153m)
Ethernet
Cat 5, Cat 5e or Cat 6 UTP (Unshielded
Twisted Pair)
305 ft
(100m)
Relay Lock Circuits 18 Stranded, shielded, w/drain
500 ft
(153m)
Branch Circuit AWG
Line 14-12
Neutral 14-12
Ground 14-12
Sub-Assembly Firmware Comments
Main Processor 4.xx.xx