EasyManuals Logo

NAPCO GEMINI GEM-P1664 User Manual

NAPCO GEMINI GEM-P1664
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
L NAPCO Security Systems
X GEM-P1664 Programming Instructions
Page 5
WI1423A 1/06
EASY MENU DRIVEN PROGRAM MODE
DEALER PROGRAM - PRELIMINARY INFORMATION
The Default Dealer Code is 4 5 6 7 8 9. Use this code to enter the Dealer Program Mode to
program a custom Dealer Code, which replaces the Default Dealer Code. If you clear your Dealer Code, use the Default Dealer
Code once again to enter programming.
After entering codes or data, press the save U button. Data will not be stored into memory unless U is pressed.
If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.
Silence the sounder by the G button to continue, or by pressing the C button to exit.
When programming a Multiple Area System, Direct Address Programming Mode must be used to complete the program.
1. Press 456789 R
2. Press "PRIOR/NO" button until TURNON PROG Y/N(GEM-RP2ASe2/
GEM-K2AS) or 17 (GEM-RP3DGTL/GEM-K3DGTL or
GEM-RP4RFC/GEM-K4RF) appears on the LCD screen.
3. Press "NEXT/YES" button to Enter Dealer Program Mode.
4. Press CC to exit Dealer Program Mode when finished.
Dealer Code (Default = 456789)
Number of Zones in Area 1
Panel Zone Doubling
Fire Zones in Area 1
2-Wire Fire Zones in Area 1
Local or Central Station Reporting System
Exit/Entry Zones in Area 1
Interior Zones in Area 1
24 Hour Zones in Area 1
Chime Zones in Area 1
Chime 2 Zones in Area 1
Exit/Entry2 Zones in Area 1
50mS Loop Response Zones (Note: 750mS is
required for Loop Response time in UL installations)
Aux Output Activated on Alarm Zones
Sensor Watch Zones
Keypad Sounder on Alarm Zones
Auto Bypass re-entry Zones
Enable no EOLR Zones
Enable Telco Line Fault Test
Enable Burg Output Chirp on Keyfob
Enable CP-01
Number of Keypads in Area 1
Central Station Receiver 1 Tel. Number
Central Station Receiver 1 Account Number
Central Station Receiver 1 Format
Enter User Codes
RF Transmitter Points
Quick Enroll Method
Key Fob Transmitters
Enter Zone Descriptions
Dealer Code
Test Timer
NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by any
means, the number zones will be suppressed and cannot be changed. Should it be necessary to create a new custom default
program, (a) from the Dealer Program Mode, press the
C button to enter the Direct Address Program Mode; (b) access Location
2285 (Clear Program); (c) press the
U button and start over.
Easy Menu Driven Program Mode
ACCESSING DEALER PROGRAM MODE
CUSTOMIZING A DEFAULT PROGRAM
For new panels, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for:
This procedure will automatically set up system keypads, EZMs, wireless transmitters, etc. After your basic default program has
been loaded, you may alter it as necessary in the Direct Address Program Mode.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO GEMINI GEM-P1664 and is the answer not in the manual?

NAPCO GEMINI GEM-P1664 Specifications

General IconGeneral
BrandNAPCO
ModelGEMINI GEM-P1664
CategoryControl Panel
LanguageEnglish

Related product manuals