L NAPCO Security Systems
X GEM-P1664 Programming Instructions
Page 9
WI1423A 1/06
GEM-RP2ASe2/GEM-K2AS--Easy Menu Driven Program Mode
Central Station Receiver 1 Account Number
Enter an account number of up to four digits. Use number buttons
1 through 9 for digits 1–9. NOTE:
Press the
G 0 buttons for a zero and press 0 for a blank space (•). Press U to save. Press the
NEXT/YES button to proceed.
NOTE: Central Station Receiver 2-4 Account Numbers can only be entered in Direct Address Programming.
See CS Reporting Options.
Central Station Receiver 1 Format
From the table below, enter the central station's receiver format. Use number buttons
1 through 9.
NOTE: Press the
G 0 buttons for a zero and press 0 for a blank space (•). Press G 1
through G 4 for letters B–E, respectively. Press U to save. Press the NEXT/YES button to
proceed.
NOTE: Central Station Receiver 2 and 3 Formats can only be entered in Direct Address Programming. See
CS Receiver Options.
Enter User Codes (Press the (
R) button to set cursor.)
For default program, enter up to 64 User Codes, with Area 1-4 Options.
Press
R once to set the cursor to the User Code. Use the number buttons 1 through 9 to
enter a code from 3 to 6 digits. Enter up to 6 digits (4 digits is recommended) in the first six boxes from
left to right for each user code. Valid entries are: 0-9. NOTE: Press 0 for a zero and press
G0 for a blank space (•). No blank spaces in between; leave blank (•) any trailing boxes. If
“Enable Global Ambush Code” (Address 0720) is enabled and “Global Ambush Code” (Address 1054) is
not left blank(•), do not program the first two digits of ANY User Code the same as the “Global Ambush
Code”. Note: If the programmed code was less than 6 digits, press R to set the cursor to the Area 1
Options Level (OPT). Refer to the table on the next page for the available area options. Note: Duplicate
User Codes are not allowed; therefore a duplicate Code entered in the LCD Window will erase when
U is
pressed.
DATA ENTRY CS RECEIVER 1 FORMAT
•(blank) Ademco Slow, Silent Knight Slow
2 Radionics Fast
3 Silent Knight Fast
4 Radionics, DCI, Franklin Slow
DATA ENTRY CS RECEIVER 1 FORMAT
5 Universal High Speed
B SIA
C Ademco Point ID
E Pager
(Direct Entry)
Acc #
(____)
(Direct Entry)
RecFmt
( )
(Direct Entry)
User01
______
(Direct Entry)
OPT__
(Direct Entry)
ACC __