19.0 MAINTENANCE AND TROUBLESHOOTING
19.1 AIR FILTER
19.2 LUBRICATION
H3.25
DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE FURNACE BEFORE ATTEMPTING
ANY MAINTENANCE. FAILURE TO DO SO CAN CAUSE ELECTRICAL SHOCK RESULTING IN
PERSONAL INJURY OR LOSS OF LIFE.
WARNING
!
!
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
ALWAYS VERIFY PROPER OPERATION AFTER SERVICING.
CAUTION
!
!
H23.2
The air lter should be inspected frequently and cleaned or replaced as necessary. We recommend a monthly
inspection at rst, perhaps coinciding with the arrival of the monthly fuel bill as a reminder. The frequency may
be increased or decreased depending on experience and conditions.
Dirty lters result in higher than normal operating temperatures, reduced air ow and lower ef ciency.
Some paper media high ef ciency lters, sometimes identi ed as HEPA lters can do an effective and
excellent ltration of the air; however, some models may also cause a large pressure drop across the lter. The
contractor should assess the capabilities of the duct system to deliver suf cient air ow if this type of lter is
considered.
RECOMMENDED: Electronic air cleaners using electrostatic precipitation to remove dust are an excellent ltration
device when used in conjunction with a pre- lter. A 16”
x 25” (406mm x 635mm) model is an ideal t with this
furnace in the case of a side mounted return air inlet. The
integrated furnace control is supplied with an electrical
terminal for use with electronic air cleaners.
NOTE
If two return air inlets are used, both must be equipped
with lters.
DO NOT OPERATE THE FURNACE FOR PROLONGED PERIODS OF TIME WITHOUT AN
AIR FILTER.
A PORTION OF THE DUST ENTRAINED IN THE AIR MAY LODGE IN THE SUPPLY AIR
DUCTWORK AND REGISTERS. ANY RECIRCULATED DUST PARTICLES WILL BE HEATED
AND CHARRED BY CONTACT WITH THE FURNACE HEAT EXCHANGER. THIS RESIDUE
WILL SOIL CEILINGS, WALLS, DRAPERY, CARPETS, AND OTHER HOUSEHOLD ARTICLES.
CAUTION
!
!
H23.2.3
Both the exhauster motor and circulating fan motor are sealed bearing type motors. Neither requires routine
lubrication. Excess lubrication will void the warranty, shorten the service life of the motors, and will attract the
buildup of dust and dirt.