Monitoring the ft Server 4-3
Express5800/ft Maintenance
Express5800/ft series maintenance can be performed in two ways; one is to use
ESMPRO Manager for remote maintenance and the other is to use the
ft Server Utility located on the managed Express5800/ft server.
Note: To start the NEC ESMPRO Agent ft server utility installed in the
NEC Express5800/ft, type:
/opt/nec/esmpro_sa/ESMftcutil
The maintenance functions that can be executed from ESMPRO include three
types, those common to all components, those specific to particular components,
and general system settings.
The table below lists the maintenance functions for specific components in your
server and indicates how the functions of these components may be executed.
Control
Component Function
Locally
ft Server Utility
Remotely
ESMPRO
Manager
module Start/Stop yes yes
MTBF Log Clear yes yes
module Diagnostics
no no
Firmware Update yes no
Dump Acquisition (during operation) yes yes
Dump Acquisition (stopped module) yes no
CPU module
Board Switch no no
module Start/Stop yes yes
MTBF Log Clear yes yes
PCI module
module Diagnostics no no
Ethernet Adapter MTBF Log Clear yes yes
SCSI Bus Bus Reset no yes
SCSI Enclosure
SCSI Electronics
SCSI Slot
MTBF Log Clear no no
BMC Firmware Update yes no
System Quick Dump, Auto-firmware Update, Auto-
module Start
no no
SCSI Disk Preventive Disk Maintenance Setup yes no
SCSI Adapter MTBF Log Clear yes yes