92
10. Appendix
POWER STATUS LIGHT Projector status Procedure
Red (Blink*
4
) Red (Blink*
4
)
Off
When phosphor wheel status is error Please contact your dealer or service
personnel.
Red (Light) Red (Blink*
3
)
Off
Filter over time Waring Please clean up the filter and set filter
counter reset. ( page 54)
*1 Repetition to light on for 1.5 seconds / off for 1.5 seconds
*2 Repetition to light on for 1.5 seconds / off for 7.5 seconds
*3 Repetition to light on for 2.5 seconds / off for 0.5 seconds
*4 Repetition to light on for 0.5 seconds / off for 0.5 seconds
When the thermal protector is activated:
When inside temperature of the projector becomes too high or low, the POWER indicator start to red blink in a
short cycle. After this happened, the thermal protector will activate and the projector may be turned off.
In this case, please take the below measures:
- Pull out the power plug from the wall inlet.
- Place the projector in cool place if it has been placed in high ambient temperature.
- Clean the exhaust vent if dust has accumulated on.
- Leave the projector for about one hour until inside temperature gets lower.