Issue 1.0
UNIVERGE SV9100
16
System Maintenance
Check/replace
station cable.
Check MDF
connection.
Busy
Idle
BLF
Indication?
E2
SLT defective.
Cancel call
Forwarding.
Replace GCD-4LCF/GCD-8LCF .
Terminate SLT on MDF.
1.
Reset/replace GCD-4LCF/GCD-8LCF and test.
2.
Perform Second Initialization, and test; then
perform
First Initialization and test.
3.
Change GCD-CP10 and test using default
program.
Replace SLT.
Check to see if ringing
problem is
intermittent.
Check to see if SLT is
call
forwarded.
Check BLF indication
for
station.
Ringing Problem on SLT
Yes
Problem
solved?
No
No
Intermittent
Problem?
Yes
No
Yes
Call
Forward?
Check GCD-4LCF /GCD-8LCF for
ring voltage output with
AC
meter.
Pass
Fail
RSG Test?
Busy
BLF
Indication?
Idle