UNIVERGE SV9100
Issue 1.0
System Maintenance Manual
69
Summary of SV9100 Alarms
Alarm
No.
Type
Name
Content of Alarm
Cause
Action
Recovery
1
Minor
PKG Initialize
Error.
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
1. PKG not inserted firmly.
2. PKG was removed, but
not reinserted firmly.
3. Old PKG data still
reported due to no
initialization.
1. Insert PKG firmly.
2. Insert PKG firmly.
3. Delete slot
information in
PRG 90-05 and
reinsert the PKG.
Upon initialization,
the PKG is
recognized.
2
Minor
PKG
Mounting Error
The unit did not step on
a regular procedure and
it was pulled out. Or, it is
not normally inserted.
1. The package is half.
2. The package is out of
order.
1. Please insert the
package firmly.
2. Please try again
after initializing the
system data once
when LED doesn't
blink normally. 3.
Exchange of packages.
When the unit is
reconfirmed, the
error is recovered.
3
Minor
Communication
fault between
CD-CP00 and
other PKGs.
The error occurred when
communicating with the
package. When the
package is broken, it
recognizes it as a
communication fault.
1.The unit is half. Minor.The
power-supply voltage of the
system is outside ratings.
3.The equipment that
generates the noise in the
same power supply system
as the power supply origin
of the system is connected,
and it malfunctions because
of the power supply noise.
4.The equipment to which it
is adjacent to of a main
device, and has put out the
radiation noise exists, and it
malfunctions because of the
radiation noise. 5.The
chassis is not properly
grounded.
1.Please insert the unit
firmly.
Minor.The power-
supply voltage must
use another power
supply when is in the
range of ratings or
measuring with the
voltmeter, and
deviating from the
rated range.
3.Please use the
power supply besides
the equipment with
the possibility of the
noise source.
4.Please separate as
much as possible and
use a main device
from the equipment
by which you seem
may generate the
radiation noise.
5.Please ground the
chassis correctly.
When the unit is
reconfirmed, the
error is recovered.