UNIVERGE SV9100
Issue 1.0
System Maintenance Manual
83
Alarm Report via e-mail
Refer to the SV9100 Features and Specifications Manual for details of Alarm Reports via e-mail.
The following SV9100 system setup is copied from the SV9100 Features and Specifications Manual.
Program
Number
Program Name/Description
Input Data
Default
10-12-01
GCD-CP10 Network Setup IP Address
Assign the IP Address.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.254.255.254
192.0.0.1 ~ 223.255.255.254
192.168.0.10
10-12-02
GCD-CP10 Network Setup Subnet Mask
The setting of Subnet Mask is invalid when
all Host Addresses are 0.
If the network section is: 0,
127,
128.0,
191.255,
192.0.0,
223.255.255
The setting of Subnet Mask is invalid.
128.0.0.0 | 192.0.0.0 | 224.0.0.0
|240.0.0.0 | 248.0.0.0 | 252.0.0.0
|254.0.0.0 | 255.0.0.0
|255.128.0.0 | 255.192.0.0 |
255.224.0.0 | 255.240.0.0
|255.248.0.0 | 255.252.0.0
|255.254.0.0 | 255.255.0.0 |
255.255.128.0 | 255.255.192.0
|255.255.224.0 | 255.255.240.0
|255.255.248.0 | 255.255.252.0
|255.255.254.0 | 255.255.255.0 |
255.255.255.128
|255.255.255.192
|255.255.255.224
|255.255.255.240
|255.255.255.248
|255.255.255.252
|255.255.255.254
|255.255.255.255|
255.255.255.0
10-12-03
GCD-CP10 Network Setup Default Gateway
Assign the default gateway IP address for the
GCD-CP10.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.254.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
90-10-02
System Alarm Setup Report
When enabled the system will provide
notification of events for each of the enabled
reports. This does not have to be set for
DIMLast/DIMDump files to be sent.
0 = No Report (no autodial) 1 =
Report (autodial)
0
90-11-02
System Alarm Report Report Method
When Alarm Reports are to be emailed, set
this option to 1. Email address set in
Program
90-11-08
0 = No Report
1 = Email Address
0
90-11-06
System Alarm Report SMTP Host Name
When Alarm Reports are to be emailed, set
the SMTP name (for example,
smtp.yourisp.com). Contact your ISP
(Internet Service Provider) for the correct
entry if needed.
Maximum of 255 characters
No Setting