66
Issue 1.0
UNIVERGE SV9100
System Maintenance Manual
Record Live System Activity to USB Memory
The live system activity will be saved to the USB stick; start and stop the recording using the Maintenance
Service code.
To Start the Recording
Ensure a USB Memory stick is installed to the USB drive of the GCD-CP10 card
Ensure you assign a Service Code to the Maintenance code in CMD 11-10-42 (default = none assigned)
From a Keytelephone go off hook and dial the Maintenance Service Code
MAINTENANCE
FUNCTION NO(1-3) ?
Enter 3 on the keypad
SYSTEM LOG SAVE TO USB
1:START 0:END ?
Enter 1 to begin recording to the USB
A new file will be created on the USB stick in folder DIMLOG, filename DIMLOG_YYMMDDhhmm.txt
SYSTEM LOG SAVE TO USB
SAVE START
Go on hook
The system activity will continue to be recorded to the USB stick
To stop recording
From a Keytelephone go off hook and dial the Maintenance Service Code
MAINTENANCE
FUNCTION NO(1-3) ?
Enter 3 on the keypad
SYSTEM LOG SAVE TO USB
1:START 0:END ?
Enter 0 to stop recording to the USB
SYSTEM LOG SAVE TO USB
SAVE END
Go on hook