System Maintenance Manual
Output the Alarm Report to a USB stick
The alarm report can be output to the memory stick installed into the USB socket of the GCD-CP10 card.
The report is generated via the Maintenance Service code.
Ensure you assign a Service Code to the Maintenance code in CMD 11-10-42 (default = none assigned).
To Output the report
Ensure a USB Memory stick is installed to the USB drive of the GCD-CP10 card
Ensure you assign a Service Code to the Maintenance code in CMD 11-10-42 (default = none assigned)
From a Keytelephone go off hook and dial the Maintenance Service Code
Enter 2 on the keypad
Enter # on the keypad to output new alarms since??
Or enter * on the keypad to output all alarms
While saving the display shows
When complete the display shows
Press SPK or go on hook to end
The alarm report is saved as a text file.
The filename is ALM_YYMMDD_HHMMSS.txt