SECTION 6 COMMON DIM COMMANDS
Enter
Function
DIM Output
Mail in 0 0 0 0
Output of all system activity is
turned on.
No ISDN information output.
Enter CAPS debug mode.
The activity of all extensions and lines is
output.
Mail in 0 0 0 0
Output of all system activity
is
turned off.
Exit CAPS debug mode.
Enter
Function
DIM Output
Mail in 0 0 1 2
Output of all ISDN activity on
the system is turned on.
Enter ISDN debug mode.
master current bid
: xxH
master current line : xxH
The activity of all ISDN blades will be output.
Mail in 0 0 1 2
Output of all ISDN activity on
the system is turned off.
Exit ISDN debug mode.
When the ISDN output is turned on, the DIM will output the ISDN blade slot and
circuit that is
currently set as the master clock for the system.
The slot number is shown by master current bid : xxH (xx is the slot number in
hexadecimal).
The circuit of the blade is shown by master current line : xxH (xx is the circuit number
in hexadecimal).