P285U00
05 - 2007
TECHNICIAN MENU
41
4.2.4 - MANUAl INSTAll.
4.3 - AUTOTEST
4.2.4
manual InStallatIon
This function is used for manually installing the boilers and lling
the water system.
4.3
autoteSt
This function allows testing, in a semiautomatic way, of the main
machine components.
It is possible to cancel each operation and go to the next one by
pressing the exit button, but conrming with the conrm button to
start the autotest routine.
Some checks occur automatically, others need the manual opera-
tion of the monitored component.
In a sequence:
- the steam exhaust fan is activated for a few seconds
- the doser units are activated for 2 seconds
- the mixers are activated for 2 seconds
- (only for the brewer units that are actually present) the brewer
unit is rotated (grinding for the espresso brewers) and a coffee
dose is dispensed
- waste tray button; the machine waits until the waste tray is re-
inserted or the button is pressed manually
- espresso safety switch test; the machine waits until the compart-
ment is re-inserted or the button is pressed manually
- push-button panel test; the machine will indicated on the display
the number and by means of illumination the button which must be
pressed and awaits the actuation before going to the next button
- boiler temperature reading
- sound signal actuation
- coin mechanism test; checking that communication with the coin
mechanism takes place correctly and which validator lines are
set as being active (only if the coin mechanism is present and set
correctly).