ProCoder™)R900i™ Installation and Maintenance Guide 3
Chapter 2: Specifications
This chapter provides the specifications for the ProCoder™)R900i™.
Electrical Specifications
The ProCoder)R900i is powered by a lithium battery.
Transmitter Specifications
Specification Description
Transmit Period l Every 14 to 20 seconds (standard R900
®
mobile message)
l Every seven and one-half minutes (standard R900 fixed network
message)
l Every three hours (standard LoRa
®
fixed network message
Transmitter Channels 50 (R900 mobile and fixed) and 64 (LoRa fixed network message)
Channel Frequency 902-928 MHz
Output Power Meets FCC Part 15.247
FCCVerification Part 15.247
Table 1 – Transmitter Specifications
Environmental Conditions
Condition Description
Operating Temperature –22º to 149ºF (–30º to 65ºC)
Storage Temperature –40º to 158ºF (–40º to 70ºC)
Operating Humidity 0 to 100% condensing (pit only)
Table 2 – Environmental Conditions
Functional Specifications
Specification Description
Register Reading l Eight digits (AMR)
l Eight digits (Visual)
MIU ID l 10 digits (R900 v4)
l Nine digits (R900 v5)
Table 3 – Functional Specifications