Ness Guardpost Installation & Programming
PROGRAMMING OPTIONS SUMMARY (ALL)
Program
Option
Name
SMS
Program
Option No.
(XX) Value (YY) Description Default
Page
No.
KEY 1-23 N/A KEY, DURESS, MEDIC,
BELL, NO PAN, ERASE
Options for learning radio keys None 18
SENS 1 N/A ALARM, HOME, HOME 2,
FIRE, CHIME, ACHIME,
HCHIME, H2CHIM,
SILENT, EXCLUD
Options for the onboard sensor ALARM
SENS 2-23 N/A ALARM, HOME, HOME 2,
FIRE, CHIME, ACHIME,
HCHIME, H2CHIM,
SILENT, EXCLUD
Options for the optional radio devices 2-23 ALARM
RANGE 01 00, 01 Onboard PIR range. 00 = Low, 01 = High LOW 19
PULSE 02 01, 02, 03, 04 Onboard PIR pulse count. 1 PULS
SIGNAL N/A Radio devices signal strength check
RADJAM N/A ON, OFF, SILENT Radio jamming alarm OFF
RADSUB N/A ON, OFF Radio message substitution alarm OFF
SUPVIS 03 00, 01, 04, 08, 16, 24 Supervision time in hours. 00 = Supervision disabled OFF
LOKOUT 04 00 Alarm Lockout. 00 = Disabled, 01 = Enabled OFF 20
ENTRY 05 05, 10, 15, 20, 25, 30 Entry delay in seconds 5 sec
EXIT 06 05, 10, 15, 20, 25, 30, 35,
40, 45, 50, 55, 60
Exit delay in seconds 5 sec
SIREN 07 01, 02, 03, 04, 05 Siren time in minutes 5 min
CHIRPS 08 00, 01 External Siren Chirps. 00 = Disabled, 01 = Enabled ON
V-ARM N/A ON, OFF Voice annunciation for arming/disarming ON
V-ALRM N/A ON, OFF Voice annunciation for alarms ON 21
V-BATT N/A ON, OFF Voice annunciation for battery alarms ON
V-FALT N/A ON, OFF Voice annunciation for system faults ON
V-DEMO N/A Not available in this version
OPEN 09 00, 01, 02, 03 Open Close Reports. 00 = Disabled, 01 = ON, 02 = RESTOR,
03 = RES+OC
OFF
LOWBAT 10 00, 01, 02, 03 Low Battery Reporting. 00 = NONE, 01 = MAIN, 02 =
SENSOR, 03 = ALL
NONE
CLIENT CL1 Up to 4 digits Client account number 0000
PHONE 1 PH1 Up to 20 digits Telephone No. 1 for reporting alarms by CID, SMS or AUD none 22
PHONE 2 PH2 Up to 20 digits Telephone No. 2 for reporting alarms by CID, SMS or AUD none
GSM SG N/A Indicates GSM signal strength 0=no signal, 9=best signal
ABORT 11 00, 05, 10, 15, 20, 25, 30,
35, 40, 45, 50, 55, 60
Dialler Abort delay in seconds. 5 sec
MEDIC 12 00, 05, 10, 15, 20, 25, 30,
35, 40, 45, 50, 55, 60
Medical Key Abort delay in seconds. 20 sec 23
T-CALL 13 00, 01, 07, 14, 30 Test Call interval in days. 00=Test Calls disabled OFF
(7 DAY when
dialler = CID)
DIALER 14 00, 01, 02 Dialler reporting format
00 = Contact ID (CID), 01 = SMS, 02 = Audible
CID
POWER 15 01, 02, 03, 04, 05, 06,
07, 08
01 = BATT, 02 = BAT-30, 03 = BAT-1H, 04 = BAT-2H, 05 =
AC-ON, 06 = SLR-30, 07 = SLR-1H, 08 = SLR-2H
BATT 24
DEFALT N/A
ALL, OPTION, KEY, SENSOR
Reset factory defaults N/A
P-EXIT N/A Press the ON button on your radio key to exit program mode. N/A
Only
available by
SMS
V Request current programmed options. Guardpost replies with
the current values of all programmed options
N/A
Options numbers marked “N/A” are not available for programming by SMS.
See page 28 for a version of this options summary showing only SMS programming options.