Configure System Information
50
Insight Managed 8-Port Gigabit Ethernet Smart Cloud Switch with 2 SFP Fiber Ports
• If you select the DayLight Saving (DST) Recurring, Recurring EU, or Recurring
USA radio button, configure the settings that are shown in the following table.
Field Description
Begins At These fields are used to configure the start values of the date and time.
• W
eek. Configure the start week.
• Day. Configure the start day
.
• Month. Configure the start month.
• Hours. Configure the start hour
.
• Minutes. Configure the start minutes.
Ends At These fields are used to configure the end values of date and time.
• W
eek. Configure the end week.
• Day. Configure the end day
.
• Month. Configure the end month.
• Hours. Configure the end hour
.
• Minutes. Configure the end minutes.
Offset Configure recurring offset in minutes. The valid range is 1–1440 minutes.
Zone Configure the time zone.
• If you select the DayLight Saving (DST) Non Recurring radio button, configure the
settings that are shown in the following table.
Field Description
Begins At These fields are used to configure the start values of the date and time.
• Month. Configure the start month.
• Date. Configure the start date.
• Y
ear. Configure the start year.
• Hours. Configure the start hour
.
• Minutes. Configure the start minutes.
Ends At These fields are used to configure the end values of date and time.
• Month. Configure the end month.
• Date. Configure the end date.
• Y
ear. Configure the end year.
• Hours. Configure the end hour
.
• Minutes. Configure the end minutes.
Offset Specify the number of minutes to shift the summer time from the standard time. The
valid range is 1–1440 minutes.
Zone Specify the acronym associated with the time zone when summer time is in effect.
This field is not validated against an of
ficial list of time zone acronyms.
8. Click the Apply button.
Your settings are saved.

Table of Contents

Other manuals for NETGEAR GC110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR GC110 and is the answer not in the manual?

NETGEAR GC110 Specifications

General IconGeneral
Switch typeManaged
Quality of Service (QoS) supportYes
Console portRJ-45
Power connectorDC-in jack
SFP module slots quantity2
Installed SFP modules quantity-
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)
Basic switching RJ-45 Ethernet ports quantity8
Product colorGray
10G supportNo
MAC address table- entries