- ENGLISH -
- 88 -
TECHNICAL DATA
SPECIFICATIONS FOR THE CABLING OF THE NETWORK CABLE
To connect the device to the Ethernet (10Base-T) or Fast Ethernet (100Base-T) network, a UTP
(Unshielded Twisted Pair) or STP (Shielded Twisted Pair) cable with RJ45 connectors is required.
The cable must conform to the standard IEEE 802.3u 100Base-T with 2 pairs of UTP cables of
category 5 or higher. The cable between the adaptor and the hub must not be more than 100m and
not less than 2.5m.
NETWORK CABLE CONNECTIONS
Signal Pin # to Pin #
TX+ 1 Å Æ 1
TX-
2 Å Æ 2
RX+
3 Å Æ 3
RX-
6 Å Æ 6
pins 1 and 2 must be connected to one twisted pair, pins 3 and 6 to another
SIGNALS ON THE “SERIAL” CONNECTOR
SERIAL
12345
6
7
89
PIN # SIGNAL
1 n.c.
2 RXD
3 TXD
4 DTR
5 GND
6 n.c.
7 RTS
(1)
+5V
(2)
8 n.c.
9 n.c.
(1)
BUS sensori
(2)
n.c. = not connected
(1)
With default jumper configuration
(2)
With environmental sensors jumper configuration