EasyManua.ls Logo

NetModule NB800 Series - COM;IO Shield; Specification of COMIO Shield; Pin Assignments of COMIO Shield

NetModule NB800 Series
225 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NBB-800
User Manual for NRSW version 4.5.0.100
3.4.11. COM/IO Shield
The COM/IO Shield has the following specification:
Feature Specification
Feature 1xRS-232/485
1xdigital input
1xdigital output
RS-232 Signals TX, RX
RS-232 Signal Level High > 5 VDC, low < -5 VDC
RS-232 Bitrate Up to 1 Mbit/s
RS-485 Signals A,B
RS-485 Signal Level Differential output, 1.5 VDC- 3.5 VDC
RS-485 Bitrate Up to 1 Mbit/s
RS-485 Termination 120 configurable by SW
DI Signals +, -
DI Level Low: 0 VDC- 3 VDC, high: 0 VDC- 32 VDC
DO Signals NO, COM
DO Level 0-32 VDC/1A
DIO Isolation 1500 VDC
Connector type 8 pin terminal block header 3.5mm
Table 3.17.: Specification of COMIO Shield
Pin Assignment
Pin Signal
V+ V+
V V, RS232 GND
1 RS232 RX (NB800 Input); RS485 A (Half-Duplex)
2 RS232 TX (NB800 Output); RS485 B (Half-Duplex)
3 In- (Digital Input isolated)
4 In+ (Digital Input isolated)
5 Out NO (Digital Output isolated, Relay contact normally open)
6 Out COM (Digital Output isolated, Relais common)
Table 3.18.: Pin Assignments of COMIO Shield