Parameter Supervision Settings
Ping interval The interval in seconds at which pings are transmitted on each inter-
face
Retry interval The interval in seconds at which pings are re-transmitted in case a
first ping failed
Max. number of failed trials The maximum number of failed ping trials until the link will be declared
as down
Emergency action The emergency action which should be taken after a maximum down-
time has been reached. Using reboot would perform a reboot of the
system, restart link services will restart all link-related applica-
tions including a reset of the modem.