To clean the TPH, begin by removing the cassette drawer from the
a cotton swab dipped in Denatured Alcohol, gently
slide the cotton swab over the TPH Printing Surface. You can do this
until the alcohol evaporates, but never use excessive force on the
TPH. You can also swab down the Peel Sensor as this device may
also accumulate dust or debris.
You can also use a TPH Cleaner Pen instead of the cotton swab and
Denatured Alcohol. The pen is available through your ACOM
When you are done cleaning the TPH, you can replace the cassette
drawer mechanism and test the print quality
Make sure that the TPH and the Peel Sensor are COMPLETELY dry of
the alcohol before plugging the scale into an AC outlet.
need to clean the Gap Sensor from time to time. To do so, please
follow the instructions located on the cassette drawer.
If you require more thorough or robust cleaning
ACOM Dealer.
Power Requirements
The NETS is designed to be used virtually anywhere in the world. Like
many appliances of today, the NETS is designed with an auto
switch power supply (SMPS.) T
his allows operation when connected to
an AC source supplying 85V to 240V AC at 50/60Hz.
Remember, an SMPS does not guarantee
improperly wired power outlet will allow the scale to operate trouble