Alter Chime Circuits - [2.5]
This menu option allows the master users to select which detection circuits are designated as
"Chime". Once programmedasChimeallusers that have access to “Usermenu 1can select
one of the six Chime options. See "Enable Chime" on page 19.
1. Ensure that “User menu 2" is selected.
Press 5 to select the Alter Chime Circu its
option. The display will show:
2. Select the circuit by entering its
number or by pressing:
A To move up one circuit
C To move down one circuit
3. e.g., for circuit 07 enter 07", the top line
of the display shows the circuit text (if
programmed) and the bottom line shows
whether the circuit is selected as “Chime” or
“Silent e.g.:
4. Press B to toggle between “Chime
and Silent”. If a low tone is generated when
pressing“Bthentheselectedcircuitcannot
be programmed as Chime”.
5. Repeat from step 2 for other circuits,
when finished press ] to abandon this
option and return User menu 2".
Alter 24 Hr Gro up - [2.6]
Detection circuits types 24Hr and Auxiliary” can be grouped together so that if required the
users can omit the group when the system is unset.
1. Ensure that “User menu 2" is selected.
Press 6 to select the Alter 24hr G roup
option. The display will show:
2. Select the circuit by entering its
number or by pressing:
A To move up one circuit
C To move down one circuit
e.g., for circuit 10 enter “10", the top
line of the display shows the circuit text
(if programmed) and the bottom line
shows whether the circuit is selected as
“Armed” or Omitted”, e.g.:
28
User Menu 2 TS790 & TS90 0 User Manual
Entrance Door
CCT 07 Silent
CCT 07-S
07-S
Alter Chime ccts
Enter CCT No.>--
LCD
CCT 01-S
Starburst
01-S
LED
Entrance Door
CCT 07 Chime
CCT 07-C
07-C
Alter 24Hr Group
Enter CCT No.>--
LCD
CCT 01-A
Starburst
01-A
LED
Loading Bay Door
CCT 10 Armed
CCT 10-A
10-A