3
Getting Started
3.5 CONNECTING MAIN POWER
Connect the ac main power connections as shown in Figure 3-8.
Warning: Do not connect AC power to your device until you have completed all input
and output connections. This device must only be installed by a specially trained
electrician with corresponding qualifications. Failure to follow all instructions and
warnings may result in injury!
Figure 3-9. Main Power Connections - AC Powered Unit
Table 3-2 shows the wire color and respective terminal connections for both USA and Europe.
Table 3-2. Main Power Connection - AC Powered Unit
WIRE COLORS
TB1 AC POWER EUROPE USA
7 ~ ac Line Brown Black
8 ~ ac Neutral Blue White
9 ~ ac Earth Green/Yellow Green
16