Modem
Reference Manual for EL470 IP Satellite Modem
Command
DmPilots
DVB-S2 Physical Layer
Pilots
Pilots
off
Off
On
0
1
Command
DmFrameType
DVB-S2 FEC-Frame
type
FEC-Frame type
Location /Modem/Control/Demodulation
Description
This variable is only visible in CCM mode and allows to configure the
DVB-S2 forward error correction (FEC) frame type :
• Normal: FEC-frames of 64800 bits or 8100 bytes.
• Short: FEC-frames of 16200 bits or 2025 bytes.
RMCP
Command
ACf Access Normal user : RW
Expert user : RW
SNMP Table ntcDevsMod01DemodulatorEntry
Command ntcDevsMod01DmFrameType
OID 1.3.6.1.4.1.5835.3.1.13.1.54.1.1
Values Factory Default
short
Enumeration Value
Short
Normal
0
1
Command
DmISIControl
ISI Control ISI Control
Location /Modem/Control/Demodulation
Description
Configuration command to control of the input stream identifier (ISI) filter:
• Enabled: ISI filtering is active.
• Disabled: No ISI filtering.
RMCP
Command
ISc Access Normal user : no access
Expert user : RW
SNMP Table ntcDevsMod01DemodulatorEntry
Command ntcDevsMod01DmISIControl
OID 1.3.6.1.4.1.5835.3.1.13.1.46.1.1
Values Factory Default
disabled
Enumeration Value
Enabled
Disabled
0
1