Reference Manual for EL470 IP Satellite Modem
Command
SyDevRmcpVer
RMCP version RMCP version
Location /Unit/Setup
Description
Readout of the current RMCP version. It allows controlling devices to
distinguish between RMCP versions and adapt their functionality
accordingly.
RMCP version 2.0 is the enhanced protocol that can be used when
designing new management systems. Contact Newtec to obtain a
copy of the separate RMCP user manual.
RMCP
Command
CRV Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01SystemEntry
Command ntcDevsMod01SyDevRmcpVer
OID 1.3.6.1.4.1.5835.3.1.1.1.26.0.1
Values Factory Default
rmcp2
Enumeration Value
V2.0 2
Command
SyDevRtc
System time System time
Location /Unit/Setup
Description
Configuration command to read or modify the real time clock. The format
is hh:mm:ss dd/mm/yyyy.
RMCP
Command
RTc Access Normal user : RW
Expert user : RW
SNMP Table ntcDevsMod01SystemEntry
Command ntcDevsMod01SyDevRtc
OID 1.3.6.1.4.1.5835.3.1.1.1.59.0.1
Values Factory Default
16:24:53
14/05/2003
String Description
length : 0 .. 19
format : \d{2}:\d{2}:\d{2} \d{2}/\d{2}/\d{4}
Command
SyDevUptime
System uptime System uptime
Location /Unit/Setup
Description
Readout of the time passed since last device boot. The data is displayed
in days, hours, minutes and seconds.
Remark: This data is the uptime of the operating system, not the uptime of
the application.
RMCP
Command
Upt Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01SystemEntry
Command ntcDevsMod01SyDevUptime
OID 1.3.6.1.4.1.5835.3.1.1.1.84.1.1