Loading...
Modem
Reference Manual for EL470 IP Satellite Modem
Variable
IfBbTxEthqMaxFilling
BB TX Eth queue max
filling
BB TX Eth queue max
Used as
variable of
Command(s)
IfBbTxEthqStats
Page
122
Description
Variable that contains the maximum filling level of the baseband TX
Ethernet queue. This queue contains the frames that travel from the
Ethernet interface to the baseband interface. The filling level is expressed
in milliseconds.
Values GUI Unit
ms
Cmd Unit Factory Default (CU)
ms 0
Expert Range (CU)
0 .. 4294967295
Variable
IfMPEGoUDPStatsRX
MtuPackets
Ethernet IN IP Ethernet IN IP
Used as
variable of
Command(s)
IfMPEGoUDPStats
Page
130
Description
Variable that contains the number of IP frames received from the Ethernet
interface.
Values GUI Unit
Packets
Cmd Unit Factory Default (CU)
Packets 0
Expert Range (CU)
0 .. 4294967295
Variable
IfMPEGoUDPStatsRXMtu
Bytes
Ethernet IN IP bytes Ethernet IN IP bytes
Used as
variable of
Command(s)
IfMPEGoUDPStats
Page
130
Description
Variable that contains the number of bytes received from the Ethernet
interface (counted at the transport layer).
Values GUI Unit
Bytes
Cmd Unit Factory Default (CU)
Bytes 0
Expert Range (CU)
0 .. 4294967295
Variable
IfMPEGoUDPStatsRXMtu
Rate
Ethernet IN Bitrate Ethernet IN Bitrate
Used as
variable of
Command(s)
IfMPEGoUDPStats
Page
130
Description
Variable that contains the bitrate received from the Ethernet interface
(counted at the transport layer).
Values GUI Unit
bps
Cmd Unit Factory Default (CU)
bps 0
Expert Range (CU)
0 .. 4294967295