EasyManua.ls Logo

Newtec EL470 - Page 36

Default Icon
275 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unit Menu
Reference Manual for EL470 IP Satellite Modem
Command
ODCurLimits
Outdoor current limit Outdoor cur. limit %
Location /Unit/Control
Description
Configuration of the current limitation for the outdoor unit. If the current to
the outdoor unit exceeds the limitation an alarm is generated.
RMCP
Command
Ocl
array : [1 .. 2]
Access Normal user :
no access
Expert user : RW
SNMP Table ntcDevsMod01ODUExtEntry
Command ntcDevsMod01ODCurLimits
OID 1.3.6.1.4.1.5835.3.1.14000.1.5.1.1.[1 .. 2]
Values GUI Unit
mA
Cmd Unit Factory Default (CU)
mA 0
Expert Range (CU)
0 .. 4000
Command
MoODU100
ODU 100 MHz
reference
ODU 100 MHz referenc
Location /Unit/Control
Description
Configuration command to control the 100 MHz outdoor unit reference
signal when an outdoor unit conditioning module is used. This 100 MHz
reference signal is needed whenever a Newtec outdoor unit is used and is
used as a reference for the local oscillator of the up-converter.
RMCP
Command
XOm Access Normal user : RW
Expert user : RW
SNMP Table ntcDevsMod01ODUEntry
Command ntcDevsMod01MoODU100
OID 1.3.6.1.4.1.5835.3.1.14.1.12.1.1
Values Factory Default
disabled
Enumeration Value
Disabled
Enabled
0
1
/Unit/Control/AES
Command
AESGroupKey
Group Key Group Key
Location /Unit/Control/AES
Description
This key is used for AES decryption of encrypted keys entered by the
user.The length of the key can be 64bits or 128bits long depending on
AES key length
The value is entered as a hexadecimal value:
64 bits - 8 bytes (16 text bytes)
128 bits - 16 bytes (32 text bytes)
RMCP
Command
AGk Access Normal user : no access
Expert user : RW
SNMP Table ntcDevsMod01SystemEntry
version 3.1