Modem
Reference Manual for EL470 IP Satellite Modem
Command
MoMonOutputMode
Monitoring output
mode
Monitor output mode
Command ntcDevsMod01MoMonOutputMode
OID 1.3.6.1.4.1.5835.3.1.3.1.52.1.1
Values Factory Default
always_on
Enumeration Value
Always on
Follow Tx
0
1
Command
MoOccBw
Occupied bandwidth Occupied bandwidth
Location /Modem/Control/Modulation/PHY
Description
Readout of the occupied bandwidth or readout of the -26 dB bandwidth of
the signal. This is calculated as the symbol rate multiplied with (1 + a) with
a = the selected roll-off factor.
RMCP
Command
Tfb Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01ModulatorEntry
Command ntcDevsMod01MoOccBw
OID 1.3.6.1.4.1.5835.3.1.3.1.25.1.1
Values GUI Unit
MHz
Cmd Unit Factory Default (CU)
Hz 8.100.000
Expert Range (CU)
1000 .. 999999999
Modem/Control/ODU
Command
ODPow
Outdoor power supply Outdoor power supply
Location /Unit/Control/ODU
Description
Configuration command to enable or disable the outdoor power supply as
delivered by the outdoor unity and LNB controller unit.
RMCP
Command
ODp Access Normal user : no access
Expert user : RW
SNMP Table ntcDevsMod01ODUEntry
Command ntcDevsMod01ODPow
OID 1.3.6.1.4.1.5835.3.1.14.1.14.1.1
Values Factory Default
disabled
Enumeration Value
Disabled
Enabled
0
1
version 3.1
92