PPA5xx/15xx communications manual
2-56
MULTIL
MULTIL
Function:
Selects data for multi string reply
Description:
Selects data values across phases and
functions that can be read in a single
string using the MULTIL? command.
Format:
MULTIL,index,phase,function
Arguments:
index:
0 clear all
1-64 select data 1-64
phase:
1-3 phase 1-3
4 sum
5 neutral
function:
1-99 see appendix B
Reply:
none
Example:
MULTIL,0
MULTIL,1,1,2 (phase 1 Watts)
MULTIL,2,2,2 (phase 2 watts)
MULTIL,3,4,3 (sum VA)
MULTIL?
3 data values returned
Notes:
For further information and assistance with the Multilog
application please go to page 2-95 where you will find an
application guide to assist with this function.