MaxNominalMinOutd. temp: / Supply
temp.
Cooling
7.52/2.37/3.175.48/1.69/3.242.06/0.38/5.3827/7 °C
EN14511 ΔT5K Output/input/EER
11.20/3.20/3.508.16/2.28/3.572.71/0.34/7.8827/18 °C
7.10/2.65/2.685.17/1.89/2.732.10/0.55/3.8235/7 °C
10.7/3.19/3.357.79/2.28/3.422.67/0.71/3.7635/18 °C
Performance, ACVM 270 and AMS 10-12
MaxNominalMinOutd. temp: / Supply
temp.
Heating
11.20/2.80/4.009.27/2.12/4.403.54/0.86/4.147/35 °C (floor)
EN14511 ΔT5K Output/input/COP
8.25/2.47/3.357.21/1.99/3.663.11/0.82/3.832/35 °C (floor)
7.46/2.58/2.896.24/2.07/3.053.29/1.07/3.09-7/35 °C (floor)
6.62/2.69/2.464.51/1.89/2.423.23/1.32/2.47-15/35 °C (floor)
11.10/3.38/3.289.08/2.58/3.553.45/0.96/3.617/45 °C
8.73/3.20/2.737.05/2.43/2.933.11/1.03/3.042/45 °C
7.22/3.26/2.215.84/2.42/2.443.14/1.40/2.25-7/45 °C
5.95/3.35/1.784.24/2.19/1.963.19/1.72/1.86-15/45 °C
8.97/3.49/2.578.41/3.08/2.754.45/1.64/2.727/55 °C
5.64/3.52/1.604.93/2.80/1.783.50/1.99/1.77-7/55 °C
MaxNominalMinOutd. temp: / Supply
temp.
Cooling
9.87/3.16/3.138.75/1.86/4.722.06/0.63/3.2827/7 °C
EN14511 ΔT5K Output/input/EER
11.7/3.32/3.5210.82/2.21/4.913.41/0.55/6.1727/18 °C
9.45/3.41/2.776.98/2.54/2.751.81/0.70/2.5935/7 °C
11.2/3.58/3.129.37/2.64/3.563.10/0.69/4.4835/18 °C