Get information
OVERVIEW
Sub-menus
service info
INFO 3
compressor info
add. heat info
alarm log
off
runs
indoor temp. log
For the menu INFO there are sever-
al sub-menus. No settings can be
made in these menus, they just dis-
play information. Status information
for the relevant menu can be found
on the display to the right of the
menus.
service info shows temperature
levels and settings in the installation.
compressor info shows operating times, number of starts etc for the
compressor in the heat pump.
add. heat info displays information about the additional heat's operating
times etc.
alarm log shows the latest alarms.
indoor temp. log the average temperature indoors week by week during
the past year.
SERVICE INFO
Menu
3.1
service info 3.1
op. prioritisation
hot water charging
hot water top
calculated flow temp.
degree minutes
outdoor temp.
charge pump speed
status
AA25
hot water
49.0 °C
52.0 °C
5.8 °C
-700
-5.6 °C
57 %
ext heat. med. pump
runs
Information about the actual operating
status of the installation (e.g. current
temperatures etc.) can be obtained here.
No changes can be made.
The information is on several pages.
Turn the control knob to scroll between
the pages.
This figure shows the number of com-
pressors that are needed for the current
demand.